J Med Life ; 17(1): 28-34, 2024 Jan.
Article En | MEDLINE | ID: mdl-38737667

This study assessed the efficacy of antimicrobial photodynamic therapy (PDT) using a 650 nm diode laser combined with methylene blue (MB) as a photosensitizer to inhibit the growth of Candida albicans (C. albicans). Oral samples were collected from 75 patients diagnosed with oral thrush. C. albicans was isolated and identified using traditional methods and the VITEK 2 YST system. Samples (n = 25) were divided into five groups: Group 1 (control, n = 5) consisted of C. albicans suspensions in saline; Group 2 (n = 5) treated with nystatin; Group 3 (n = 5) exposed to a 650 nm diode laser in continuous mode at 200 mW for 300 seconds; Group 4 (n = 5) treated with 650 nm laser and MB as a photosensitizer; Group 5 (n = 5) exposed to the laser in combination with nystatin. Statistical analysis using ANOVA, Dunnett's t-test (P = 0.05), and LSD (P = 0.001) revealed significant differences in C. albicans counts pre- and post-treatment. Group 5 showed the most significant reduction in C. albicans, followed by Group 4, while Groups 2 and 3 showed the least variation. The findings suggest that PDT using a 650 nm diode laser with methylene blue (in continuous mode at 200 mW for 300 seconds) effectively reduced the prevalence of C. albicans.


Candida albicans , Methylene Blue , Photochemotherapy , Photosensitizing Agents , Candida albicans/drug effects , Photochemotherapy/methods , Humans , Methylene Blue/pharmacology , Photosensitizing Agents/pharmacology , Lasers, Semiconductor/therapeutic use , Candidiasis, Oral/drug therapy , Candidiasis, Oral/microbiology , Nystatin/pharmacology , Antifungal Agents/pharmacology , Antifungal Agents/therapeutic use
2.
J Indian Prosthodont Soc ; 24(2): 136-143, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38650338

AIM: To evaluate and compare the effect of impregnated retraction cord vs Laser on gingival attachment level and pain perception following retraction for subgingival margins. SETTINGS AND DESIGN: Many methods for achieving and measuring the amount of gingival retraction in fixed prosthodontic work have been advocated. Though the gingival attachment level is crucial in Periodontology, the literature available regarding the effect of these retraction methods on the same is scarce. Hence, this clinical study was designed to compare the pain perception and amount of gingival recession when impregnated cord and laser were used for retraction. MATERIALS AND METHODS: In 40 subjects (age range of 20 to 40 years) with single missing maxillary incisor, the abutments were prepared with subgingival margins, to receive a full coverage metal-ceramic fixed dental prosthesis. The gingiva was retracted on one of the abutments with impregnated retraction cord and on the other with diode laser. Gingival attachment levels were compared at six sites per abutment using superimposition of digital scans, preoperative and four weeks after cementation of final prosthesis. STATISTICAL ANALYSIS USED: Statistical analysis of the data for gingival recession was done using t-test. Pain perception was analysed with Chi-square test. Pain perception by patients following retraction was compared with VAS scale. RESULTS: The average values of gingival recession on buccal side were 0.61 mm and 0.38 mm and on the palatal side were 0.58 mm and 0.35 mm for impregnated retraction cord and laser respectively. The P values of <0.01 indicated a highly significant difference between the two groups. Intragroup comparison did not show significant differences between various sites. Pain and discomfort produced by cord method was moderate in comparison with mild/no pain with diode laser and the difference was highly significant.Conclusion: Retraction cord produced more gingival recession than the diode laser, which was statistically highly significant on both buccal and palatal aspects of the teeth. Patients experience with diode laser technique was less painful in comparison with retraction cord method.


Gingival Recession , Pain Perception , Humans , Adult , Prospective Studies , Female , Male , Pain Perception/physiology , Young Adult , Gingival Retraction Techniques/instrumentation , Gingiva , Lasers, Semiconductor/therapeutic use , Pain Measurement/methods
3.
Photobiomodul Photomed Laser Surg ; 42(4): 285-293, 2024 Apr.
Article En | MEDLINE | ID: mdl-38662503

Objective: This study aims to explore the preventive potential of photobiomodulation (PBM) in bisphosphonate-related osteonecrosis of the jaw (BRONJ) using a rat model. Methods: An experimental rat model was established, exposing rats to zoledronic acid (ZA), a primary risk factor for BRONJ. An 810 nm diode laser was applied with parameters of 0.33 W/cm2 power density and 10 J/cm2 energy density for 30 sec. PBM was initiated 1 day pre-extraction and continued for 2 weeks. The impact of PBM on wound healing in both soft and hard tissues was evaluated post tooth extraction. Results: ZA exposure hindered wound healing in both soft and hard tissues after tooth extraction. PBM intervention effectively mitigated the adverse effects of ZA, promoting healing processes in both tissue types. This suggests the potential of PBM as a preventive strategy for BRONJ in patients on long-term bisphosphonate treatment. Moreover, PBM exhibited enhanced wound healing in normal rats, indicating its broader applicability beyond BRONJ cases. Conclusions: PBM shows promise in preventing and improving wound healing in BRONJ and normal cases. These findings underscore the significance of optimizing PBM parameters and suggest its potential clinical relevance as a preventive intervention for BRONJ and a promoter of wound healing.


Bisphosphonate-Associated Osteonecrosis of the Jaw , Disease Models, Animal , Low-Level Light Therapy , Rats, Sprague-Dawley , Tooth Extraction , Wound Healing , Zoledronic Acid , Animals , Bisphosphonate-Associated Osteonecrosis of the Jaw/prevention & control , Bisphosphonate-Associated Osteonecrosis of the Jaw/etiology , Rats , Zoledronic Acid/pharmacology , Wound Healing/drug effects , Wound Healing/radiation effects , Bone Density Conservation Agents , Diphosphonates/pharmacology , Lasers, Semiconductor/therapeutic use , Imidazoles/pharmacology , Male
4.
J Appl Oral Sci ; 32: e20230419, 2024.
Article En | MEDLINE | ID: mdl-38655987

OBJECTIVE: This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. METHODOLOGY: The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. RESULTS: The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. CONCLUSION: The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.


Lasers, Semiconductor , Lasers, Solid-State , Margins of Excision , Tongue , Animals , Lasers, Semiconductor/therapeutic use , Lasers, Solid-State/therapeutic use , Tongue/surgery , Tongue/pathology , Reproducibility of Results , Sheep , Connective Tissue/pathology , Epithelium/pathology , Reference Values , Oral Surgical Procedures/methods , Mouth Mucosa/pathology , Mouth Mucosa/surgery , Statistics, Nonparametric , Laser Therapy/methods , Laser Therapy/instrumentation
5.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Article En | MEDLINE | ID: mdl-38656028

PURPOSE: The purpose of this study is to assess the long-term outcomes of modified transcanalicular diode laser dacryocystorhinostomy in a large cohort of patients affected by primary acquired nasolacrimal duct obstruction. METHODS: This study, conducted from January 17 to June 2022, encompassed 141 patients (159 procedures) who underwent modified transcanalicular diode laser dacryocystorhinostomy (MT-DCR). The procedure employed an 810-nm diode laser. Patients were monitored for at least a year after the intervention. Anatomical success was determined by ostium patency upon irrigation, while functional success referred to epiphora resolution. Parameters studied included patient demographics, procedure duration, complications, and both anatomical and functional success. Statistical analysis was performed using the Statistical Package for the Social Sciences software, with results considered significant at a 95% confidence interval (p≤0.05). RESULTS: A total of 159 lacrimal drainage systems (141 patients: 112 women and 29 men) were included in this study. Among them, 18 underwent bilateral procedures. The average patient age was 58 years (range: 34-91 years), and the average surgical duration was 24 minutes (range: 18-35 minutes). One year after the surgery, MT-DCR exhibited anatomical and functional success rates of 84.9% (135/159) and 83% (132/159), respectively. CONCLUSION: MT-DCR achieved an anatomical success rate of 84.9%, reflecting an excellent outcome. However, further extensive studies with larger sample sizes and longer follow-up periods are necessary to substantiate these findings.


Dacryocystorhinostomy , Lacrimal Duct Obstruction , Lasers, Semiconductor , Humans , Dacryocystorhinostomy/methods , Female , Male , Middle Aged , Adult , Aged , Treatment Outcome , Lasers, Semiconductor/therapeutic use , Aged, 80 and over , Time Factors , Nasolacrimal Duct/surgery , Operative Time , Retrospective Studies
6.
Sci Rep ; 14(1): 9137, 2024 04 21.
Article En | MEDLINE | ID: mdl-38644422

To investigate the therapeutic potential of photodynamic therapy (PDT) for malignant gliomas arising in unresectable sites, we investigated the effect of tumor tissue damage by interstitial PDT (i-PDT) using talaporfin sodium (TPS) in a mouse glioma model in which C6 glioma cells were implanted subcutaneously. A kinetic study of TPS demonstrated that a dose of 10 mg/kg and 90 min after administration was appropriate dose and timing for i-PDT. Performing i-PDT using a small-diameter plastic optical fiber demonstrated that an irradiation energy density of 100 J/cm2 or higher was required to achieve therapeutic effects over the entire tumor tissue. The tissue damage induced apoptosis in the area close to the light source, whereas vascular effects, such as fibrin thrombus formation occurred in the area slightly distant from the light source. Furthermore, when irradiating at the same energy density, irradiation at a lower power density for a longer period of time was more effective than irradiation at a higher power density for a shorter time. When performing i-PDT, it is important to consider the rate of delivery of the irradiation light into the tumor tissue and to set irradiation conditions that achieve an optimal balance between cytotoxic and vascular effects.


Glioma , Lasers, Semiconductor , Photochemotherapy , Photosensitizing Agents , Porphyrins , Animals , Photochemotherapy/methods , Glioma/drug therapy , Glioma/pathology , Porphyrins/pharmacology , Porphyrins/therapeutic use , Mice , Lasers, Semiconductor/therapeutic use , Cell Line, Tumor , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use , Disease Models, Animal , Allografts , Apoptosis/drug effects , Male
7.
PLoS One ; 19(4): e0301630, 2024.
Article En | MEDLINE | ID: mdl-38603689

Aiming at the weak performance of chaotic light output in semiconductor laser systems, the study designed a power control algorithm for semiconductor laser drive systems based on linear self-disturbance rejection control. Then the optimization parameters and scope were determined, and multi-objective optimization and direction preference algorithms were introduced. A chaotic optical performance optimization model based on improved multi-objective genetic algorithm was constructed using adaptive functions as evaluation indicators. These results confirmed that the larger the bandwidth of the controller, the faster the response speed of the resonant converter, but the stability was poor. When the input voltage underwent a sudden change, the current ripple coefficient of the PID algorithm was 0.55%. The linear active disturbance rejection control algorithm could ensure that the voltage and current maintained at the set values, and the output current of the algorithm was more stable when the load underwent sudden changes. The directional preference algorithm could further provide more valuable solutions on the basis of adaptive genetic algorithms. When the peak value of the autocorrelation function was equal to 0.2, the delay characteristics of chaotic light were effectively suppressed, having strong signal bandwidth and complexity. In summary, the constructed model has good application effects in optimizing chaotic optical performance and has certain positive significance for communication security.


Algorithms , Lasers, Semiconductor , Communication , Reaction Time , Semiconductors
9.
Braz Oral Res ; 38: e025, 2024.
Article En | MEDLINE | ID: mdl-38597545

Treatment of oral vascular anomalies (OVA) has focused on minimally invasive techniques rather than radical surgery. We investigated the efficacy and safety of diode laser using the photocoagulation technique in the management of OVA. Forty-seven subjects with OVA were treated with forced dehydration with induced photocoagulation (FDIP) using diode laser (808 nm/4.5 W). This series consisted mostly of male (63.8%) and non-white (63.8%) patients with a mean age of 57.4 years. Varices (91.5%), venous malformations (6.4%), and hemangiomas (2.1%) with a mean size of 7.1 (±4.9) mm were the conditions treated. OVA presented as a nodular lesion (63.8%) involving mainly the lower lip (46.8%). Pulsed laser mode was used as standard and the number of applications varied from one to four sessions, with the majority requiring only one (83%) FDIP session. Kaplan-Meier analysis revealed that complete clinical healing can occur on the 15th day (n=9/29.5%), followed by the 20th (n=6/45.5%), and 30th (n=7/70.5%) days. Postoperative edema was observed in 31 (66%) patients, and recurrence of the lesion occurred in two (4.2%). Based on the data on complete clinical healing, minimal patient discomfort, and satisfactory esthetic results, we can confirm that FDIP by diode laser is a promising candidate for the safe and efficacious treatment of OVA.


Lasers, Semiconductor , Lip , Humans , Male , Middle Aged , Lasers, Semiconductor/therapeutic use , Lip/surgery , Lip/blood supply , Treatment Outcome , Wound Healing
10.
J Cosmet Dermatol ; 23 Suppl 1: 19-26, 2024 Apr.
Article En | MEDLINE | ID: mdl-38587300

BACKGROUND: The use of non-ablative fractionated lasers for skin rejuvenation has been proven to be effective in improving skin texture, and has become popular due to minimal wounding, significantly shorter recovery times and decreased adverse effects. OBJECTIVE: To retrospectively analyze improvement in skin texture in healthy women aged over 18 years with Fitzpatrick skin types II-IV. METHODS: Participants received three facial and/or neck treatments with the 1570-nm fractional scanning diode laser at 1-month intervals. Three months after the last treatment session two blinded evaluators assessed skin improvement using before and after photos. Pain and patient satisfaction were recorded. RESULTS: Sixteen women with a mean age of 45.4 ± 4.1 years (range 35-50 years) and skin type II-IV were included in the analysis. All 16 participants received facial treatments and seven (43.8%) also received neck treatments. Three months follow-up evaluation showed that the majority of participants had a visible change in the treated areas. Mean pain score was low and decreased with each treatment session. CONCLUSION: Skin treatment using fractional scanning 1570-nm diode laser improves skin laxity in women with skin types II-IV. Larger studies are warranted to further clarify the efficacy and safety of this modality.


Laser Therapy , Lasers, Solid-State , Skin Aging , Humans , Female , Adult , Middle Aged , Rejuvenation , Lasers, Semiconductor/adverse effects , Retrospective Studies , Face , Lasers, Solid-State/adverse effects , Patient Satisfaction , Pain/etiology , Treatment Outcome , Laser Therapy/adverse effects
11.
Otol Neurotol ; 45(5): 489-494, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38530360

BACKGROUND: Microdrill and diode laser are two different methods used in endoscopic stapedotomy for otosclerosis. These two methods have not been compared in endoscopic stapedotomy. AIMS/OBJECTIVES: To analyze the differences between microdrill and diode laser in endoscopic stapedotomy for otosclerosis. MATERIALS AND METHODS: This is a randomized clinical trial; patients with otosclerosis were randomly divided into microdrill group (group A: n = 69) and diode laser group (group B: n = 62). Differences between the two groups were then compared. RESULTS: The preoperative air-bone gap (ABG) was 25.40 ± 10.88 dBHL in group A and 24.84 ± 12.23 dBHL in group B, with no significant between-group difference ( p > 0.05). The postoperative ABG in group A was 13.27 ± 9.91 dBHL versus 11.79 ± 10.82 dBHL in group B, and there was no significant difference between the groups ( p > 0.05). The surgical time in group B (64 ± 31.23 minutes) was significantly longer than that in group A (48 ± 25.62 minutes) ( p = 0.02). There were no significant between-group differences in basic patient-related data, preoperative air conduction (AC), preoperative bone conduction (BC), postoperative AC, distribution of postoperative ABG, preoperative ABG at different frequencies, and postoperative ABG at different frequencies. There was also no significant between-group difference in the average bleeding volume or number of patients with postoperative dizziness. CONCLUSION AND SIGNIFICANCE: The postoperative improvement in hearing level in the two group was equivalent, but group A had the advantage of a shorter operation time. LEVEL OF EVIDENCE: 4.


Bone Conduction , Endoscopy , Lasers, Semiconductor , Otosclerosis , Stapes Surgery , Humans , Stapes Surgery/methods , Otosclerosis/surgery , Female , Male , Adult , Middle Aged , Lasers, Semiconductor/therapeutic use , Endoscopy/methods , Treatment Outcome , Laser Therapy/methods , Operative Time
12.
Sci Rep ; 14(1): 6871, 2024 03 22.
Article En | MEDLINE | ID: mdl-38519552

Previous findings indicated that the laser photobiomodulation is more effective than the control or placebo in preserving the alveolar socket. This study aimed to compare two different lasers regarding their effectiveness in aiding alveolar socket preservation. Twenty extraction sockets were selected then divided into two equal groups. Group A was exposed to 650 nm Diode laser, and Group B to 810 nm Diode laser following the same protocol and parameters after a standard alveolar socket preservation procedure with collagen plug. Radiographic analysis with cone beam computed tomography was done to compare the alveolar bone surface area immediately after extraction and three months post-operatively, while bone samples collected before implant drilling were histologically examined for newly formed bone evaluation and histomorphometric analysis in terms of percentage of new bone surface area, percentage of unmineralized bone and finally, immunohistochemical analysis of Osteocalcin reaction surface area as well as optical density. Radiographically, infrared (810 nm) Diode effect on alveolar bone surface area has significantly exceeded the red laser, while histologically, red (650 nm) Diode has demonstrated statistical significance regarding all parameters; newly formed bone surface area percentage, unmineralized bone area percentage and finally Osteocalcin bone marker reaction surface area percentage and optical density. Under the specified conditions and laser parameters, photobiomodulation using the 810 nm Diode got the upper hand radiographically, yet histologically, the red 650 nm Diode managed to dominate all histological parameters when both employed as an adjunct to alveolar socket preservation procedures.


Alveolar Bone Loss , Low-Level Light Therapy , Humans , Alveolar Process/diagnostic imaging , Alveolar Process/surgery , Alveolar Process/pathology , Tooth Socket/diagnostic imaging , Tooth Socket/surgery , Tooth Socket/pathology , Lasers, Semiconductor/therapeutic use , Osteocalcin , Tooth Extraction/methods , Alveolar Bone Loss/pathology
13.
Photobiomodul Photomed Laser Surg ; 42(4): 306-313, 2024 Apr.
Article En | MEDLINE | ID: mdl-38546858

Background: This investigation set out to compare the impacts of low-level diode laser (LLDL) and red light-emitting diode (LED) on the survival of human dental pulp stem cells (hDPSCs) and osteogenic/odontogenic differentiation. Methods and materials: In this ex vivo experimental study, the experimental groups underwent the irradiation of LLDL (4 J/cm2 energy density) and red LED in the osteogenic medium. Survival of hDPSCs was assessed after 24 and 48 h (n = 9) using the methyl thiazolyl tetrazolium (MTT) assay. The assessment of osteogenic/odontogenic differentiation was conducted using alizarin red staining (ARS; three repetitions). The investigation of osteogenic and odontogenic gene expression was performed at two time points, specifically 24 and 48 h (n = 12). This analysis was performed utilizing real-time reverse-transcription polymerase chain reaction (RT-PCR). The groups were compared at each time point using SPSS version 24. To analyze the data, the Mann-Whitney U test, analysis of variance, Tukey's test, and t-test were utilized. Results: The MTT assay showed that LLDL significantly decreased the survival of hDPSCs after 48 h, compared with other groups (p < 0.05). The qualitative results of ARS revealed that LLDL and red LED increased the osteogenic differentiation of hDPSCs. LLDL and red LED both upregulated the expression of osteogenic/odontogenic genes, including bone sialoprotein (BSP), alkaline phosphatase (ALP), dentin matrix protein 1 (DMP1), and dentin sialophosphoprotein (DSPP), in hDPSCs. The LLDL group exhibited a higher level of gene upregulation (p < 0.0001). Conclusions: The cell survival of hDPSCs was reduced, despite an increase in osteogenic/odontogenic activity. Clinical relevance: Introduction of noninvasive methods in regenerative endodontic treatments.


Cell Differentiation , Cell Survival , Dental Pulp , Lasers, Semiconductor , Low-Level Light Therapy , Odontogenesis , Osteogenesis , Stem Cells , Humans , Dental Pulp/cytology , Dental Pulp/radiation effects , Cell Differentiation/radiation effects , Osteogenesis/radiation effects , Stem Cells/radiation effects , Stem Cells/cytology , Cell Survival/radiation effects , Odontogenesis/radiation effects , Cells, Cultured , Red Light
14.
Sensors (Basel) ; 24(6)2024 Mar 20.
Article En | MEDLINE | ID: mdl-38544236

Caffeine is the most widely consumed stimulant and is the subject of significant ongoing research and discussions due to its impact on human health. The industry's need to comply with country-specific food and beverage regulations underscores the importance of monitoring caffeine levels in commercial products. In this study, we propose an alternative technique for caffeine analysis that relies on mid-infrared laser-based photothermal spectroscopy (PTS). PTS exploits the high-power output of the quantum cascade laser (QCL) sources to enhance the sensitivity of the mid-IR measurement. The laser-induced thermal gradient in the sample scales with the analytes' absorption coefficient and concentration, thus allowing for both qualitative and quantitative assessment. We evaluated the performance of our experimental PTS spectrometer, incorporating a tunable QCL and a Mach-Zehnder interferometer, for detecting caffeine in coffee, black tea, and an energy drink. We calibrated the setup with caffeine standards (0.1-2.5 mg mL-1) and we benchmarked the setup's capabilities against gas chromatography (GC) and Fourier-transform infrared (FTIR) spectroscopy. Quantitative results aligned with GC analysis, and limits of detection matched the research-grade FTIR spectrometer, indicating an excellent performance of our custom-made instrument. This method offers an alternative to established techniques, providing a platform for fast, sensitive, and non-destructive analysis without consumables as well as with high potential for miniaturization.


Beverages , Caffeine , Humans , Caffeine/analysis , Spectrophotometry, Infrared , Spectroscopy, Fourier Transform Infrared/methods , Beverages/analysis , Lasers, Semiconductor
16.
Am J Dent ; 37(1): 39-46, 2024 Feb.
Article En | MEDLINE | ID: mdl-38458982

PURPOSE: To investigate the differences between irrigant propagation and temperature changes using laser-activated irrigation (LAI) at different settings in an artificial root canal model. METHODS: Using an artificial resin root canal model, irrigant activation was achieved in 19 experimental groups with eight samples each. A 9,300 nm CO2 laser, two diode lasers with different settings (wavelengths 455, 808, 970, and 980 nm) were compared to 2,940 nm Er:YAG laser and traditional needle irrigation. Er:YAG and CO2 laser were activated in the pulpal chamber only, while diode lasers and needles were inserted into the main root canal. Lasers were activated for 5x 20 seconds resulting in 100 seconds of activation or rinsing for each sample. After each activation of 20 seconds, a photo was taken of the side canals and the propagation of the dye was measured with a digital measuring tool after calibration. Further, the temperature of the irrigant was reported after activation of 20 seconds and repeated 5 times. Data were checked for normality and statistically compared. RESULTS: All lasers increased the irrigant propagation compared to conventional irrigation. Significant differences were found between groups regarding propagation and temperature (P< 0.0027). Er:YAG and CO2 laser had similar effects on irrigant propagation in middle and apical located side-canals with specific power parameters and were superior to diode lasers and syringe irrigation. The irrigant's temperature increased significantly with the diode and CO2 lasers. CLINICAL SIGNIFICANCE: Diode lasers and CO2 lasers have not been established for irrigant activation. 9,300 nm CO2 lasers absorb well in water and were shown to introduce vapor bubble formation and streaming in water. Diode lasers are highly accepted in periodontics. The laser light is not absorbed in water but interacts with bacteria as well as soft tissues and contributes therefore to infection control. With a modified laser tip it was however possible to introduce cavitation and streaming in irrigants.


Carbon Dioxide , Lasers, Solid-State , Lasers, Semiconductor , Proof of Concept Study , Root Canal Irrigants , Dental Pulp Cavity/microbiology , Water , Root Canal Preparation/methods
18.
J Cosmet Dermatol ; 23(4): 1282-1290, 2024 Apr.
Article En | MEDLINE | ID: mdl-38348571

INTRODUCTION: Performing laser hair removal treatments on dark skin is limited by the quantity of melanin within the skin. To minimize side effects, lower values of fluence are selected when using standard 755 or 810 nm diode lasers. However, this approach may limit the effectiveness of the procedure, particularly when treating areas with thin and less pigmented hair, which is often the case in facial regions. To improve results, high-power triple wavelength diode lasers can be used. This study aims to assess the efficacy, safety, and comfort of treatments that remove facial hair with a high-power triple wavelength diode laser (810, 940, and 1060 nm) in static mode on Asian patients with thin and less pigmented hair. MATERIALS AND METHODS: A single-center retrospective cohort study was carried out using a high-power triple wavelength diode laser (810, 940, and 1060 nm), with a 2.7 cm2 spot size, on faces with thin and less pigmented hair. The study comprised 23 subjects with Fitzpatrick skin types IV and V. Effectiveness was measured by counting the hairs that appeared in high-resolution photos taken prior to and following the procedure, in addition to the Global Aesthetic Improvement Scale (GAIS). Furthermore, mathematical 3D simulations were created on the COMSOL Multiphysics® software to allow for comparisons to be made with regard to thermal damage sustained by the hair follicles and epidermal heating. Assessments were also made in relation to side effects. RESULTS: An average of 66% hair reduction was observed. Patient satisfaction was between 4 and 5 points on the GAIS scale, indicating that the treatment was very well received and tolerated. Adverse side effects were not observed. CONCLUSION: It can be concluded that the use of a high-power triple wavelength diode laser (810, 940, and 1060 nm) is safe and effective for the treatment of very fine and less pigmented facial hair on Asian skin. Furthermore, a triple wavelength (810, 940, and 1060 nm) laser is absorbed less by the melanin in the skin, enabling the use of higher fluences in stamping mode, with greater efficacy and safety for darker skin.


Hair Removal , Lasers, Semiconductor , Humans , Lasers, Semiconductor/adverse effects , Retrospective Studies , Melanins , Treatment Outcome , Hair , Hair Removal/adverse effects , Hair Removal/methods
19.
Lasers Surg Med ; 56(3): 233-238, 2024 Mar.
Article En | MEDLINE | ID: mdl-38334165

OBJECTIVES: Ultraviolet light and infrared radiation exposure to the chest and neck can result in photoaging changes, such as rhytids, skin roughness, and dyschromia, which can be treated with nonablative fractionated lasers. The low-powered fractionated 1440 and 1927-nm diode lasers have been shown to safely reduce facial photodamage. This study was conducted to investigate the safety and efficacy of a low-powered 1440 and 1927-nm nonablative fractionated diode laser in addressing photoaging symptoms, such as rhytids, skin roughness, and dyschromia, of the neck and chest. METHODS: In a prospective, single-arm, nonrandomized study, a cohort of 24 adult female patients with photodamage to their neck and chest received four treatments to these areas, administered at 4-week intervals. Treatments consisted of four passes on high settings with the 1440 nm handpiece followed by four passes with the 1927 nm handpiece. Photographs were taken at each study visit. Study investigators graded wrinkle severity, texture, and mottled pigmentation of the treated area at baseline and follow-up visit, 3 months after the fourth treatment. Subjects also rated clinical improvement of their neck and chest, along with overall appearance. Blinded evaluators used baseline and follow-up photographs to quantify improvements of rhytids and hyperpigmentation of the neck and chest using a 6-point improvement scale. RESULTS: Of the original cohort, 20 subjects completed all four treatments and 3-month follow-ups. The mean rhytid scores improved by 0.7 ± 1.0 for both neck and chest. Meanwhile, texture scores improved by 1.2 ± 0.4 for the neck and 1.4 ± 0.7 for the chest, with pigment scores improving by 0.5 ± 0.6 for the neck and 0.67 ± 0.7 for the chest. Statistical analysis using paired t-tests, performed on all pre- and posttreatment scores, revealed significant differences (p < 0.05) in wrinkle severity, skin texture, and pigmentation of the neck and chest posttreatment. The degree of improvement was consistent for both the neck and chest areas. Blinded evaluators graded clinical improvements in rhytids and pigmentation at 0.6 ± 1.0 and 0.8 ± 1.2 respectively, corresponding to mild improvement of both neck and chest. CONCLUSIONS: A series of treatments with the nonablative low-energy fractional 1440 and 1927-nm diode laser appears to be safe and effective for improving rhytids, skin texture, and hyperpigmentation of the neck and chest.


Hyperpigmentation , Lasers, Solid-State , Skin Aging , Adult , Humans , Female , Treatment Outcome , Follow-Up Studies , Lasers, Semiconductor/therapeutic use , Rejuvenation , Prospective Studies , Lasers, Solid-State/therapeutic use
20.
BMC Oral Health ; 24(1): 270, 2024 Feb 23.
Article En | MEDLINE | ID: mdl-38395824

BACKGROUND: Periodontitis is a microbially induced disease destroying structures anchoring teeth to jaw bones. Although metronidazole in combination with spiramycin is the effective conventional treatment of stage III grade C periodontitis, it has several systemic side effects. Laser therapy is widely used nowadays as an adjunct to scaling and root planing (SRP) to modulate inflammatory host response and eradicate microbes, due to bactericidal and detoxifying effects. Since microbiological analysis is one of the diagnostic methods identifying periodontal risk; our research aimed to investigate the efficacy of intra-pocket application of diode laser (980 nm) versus antibiotic therapy in enhancing clinical and microbiological parameters in stage III grade C periodontitis. METHODS: A randomized controlled clinical trial was conducted on fifty patients with stage III grade C periodontitis, divided equally into two groups. We managed test group by SRP with intra-pocket application of diode laser (980 nm) and the control group by SRP with systemic antibiotic administration (spiramycin and metronidazole). Then, we measured periodontal pocket depth (PPD) and clinical attachment loss (CAL) for both groups, before treatment (baseline), four and twelve weeks after. Moreover, we collected gingival crevicular fluid from both groups at baseline, four and twelve weeks after treatment and analyzed by real-time polymerase chain reaction to detect the relative count of Aggregatibacter actinomycetemcomitans and Porhyromonas gingivalis. RESULTS: Compared to baseline, all assessed clinical and microbiological parameters attested improvement at the end of the study period in each group individually with no significant difference between the two studied groups. Although, at twelve weeks, flare up of bacterial levels was detected with systemic antibiotic administration. CONCLUSION: Laser therapy can be considered as an effective treatment modality in stage III grade C periodontitis, avoiding the systemic antibiotic side effects and solving the recurrence problems due to bacterial resistance by long term usage. TRIAL REGISTRATION: NCT05222737 retrospectively on 03/02/2022, Clinicaltrial.gov.


Chronic Periodontitis , Periodontitis , Spiramycin , Humans , Metronidazole/therapeutic use , Spiramycin/therapeutic use , Lasers, Semiconductor/therapeutic use , Retrospective Studies , Follow-Up Studies , Periodontitis/drug therapy , Periodontitis/microbiology , Anti-Bacterial Agents/therapeutic use , Dental Scaling/methods , Root Planing/methods , Chronic Periodontitis/therapy
...